Papua New Guinea 15W power adapter

Model: SOY-1200120EU Brand: SOY Type: 12V1.2A switching power adapter Output voltage: 12V Output current: 1.2A Input voltage: 100-240V AC Working frequency: 50-60Hz Size: 72.7 x 40.7 x 28 mm Material: PC + ABS No-load power consumption: 0.1W

Product Description

15w power adapter

Technical Parameters

Model SOY-1200150US
Brand SOY
Type 15W power adapter
Output voltage 12V
Output current 1.5A
Input voltage 100-240V AC
Working frequency 50-60Hz
Size 72.7 x 40.7 x 28 mm
Material PC + ABS
No-load power consumption 0.1W
Energy efficiency Level VI or V
Safety standards CE

1. Certified

CE (60950)

model Output (V) Output (A) Output (W) Maximum current (MAX)
SUN-1200120EU 5-12V 0.1A-1.2A 15W (MAX) 0.6A
SOY-1200120EU 5-12V 0.1A-1.2A 15W (MAX) 0.6A
2. Reliability

Ageing: The product should be cooked for at least 2-4 hours in an environment of 40 ° C ± 5 ° C and 80% of the rated load.

MTBF Qualification

Mean time between failures: 30,000 hours, 25 ° C environment and rated input and full load conditions

3. Protection function

Short circuit protection:

The power adapter will have a self-limiting protection function to prevent short-circuit or overload conditions.The power supply will not be damaged under continuous or intermittent short-circuit conditions.After the short-circuit is removed, the power supply will automatically resume normal operation.

Overcurrent protection:

When the output current of the power supply reaches 1.8 ~ 3.0A, the overcurrent protection will be activated. After the overcurrent fault is removed, the power supply will automatically resume normal operation.

4. Environmental requirements

Operating temperature:0 ℃ -40 ℃, full load, normal work

5.EMS standard

EN 61000-3-2

Harmonic current emissions

EN 61000-3-3

Voltage fluctuations & flicker

EN 61000-4-2

Electrostatic Discharge (ESD): 8kV air discharge, 4kV contact discharge

EN 61000-4-3

Radio-Frequency Electromagnetic Field Susceptibility Test-RS

EN 61000-4-4

Electrical Fast Transient / Burst-EFT

EN 61000-4-5

Surge Immunity Test: AC Power Line: line to line 1kV

EN 61000-4-6

Conducted Radio Frequency Disturbances Test-CS

EN 61000-4-8

Power Frequency Magnetic Field Test

EN 61000-4-11

Voltage Dips